  • Determines Vicat Softening Temperature (VST) by heating the specimen at a controlled rate until a standard Ø1 mm test head penetrates to the target depth.
  • Touchscreen, step-by-step guided interface with real-time station temperature and deflection display plus automatic recording and cooling.
  • Supports Method A (10N) and Method B (50N), with deflection reading 0.001–3.000 mm.
Interested?

Request a quote for this product

  • Determines Vicat Softening Temperature (VST) by heating the specimen at a controlled rate until a standard Ø1 mm test head penetrates to the target depth.
  • Touchscreen, step-by-step guided interface with real-time station temperature and deflection display plus automatic recording and cooling.
  • Supports Method A (10N) and Method B (50N), with deflection reading 0.001–3.000 mm.
  • Up to 300°C with circulation flow temperature equalization and water cooling.
  • Available in 1, 2, or 3 stations for higher lab throughput.

Overview

The Cometech QC-662B Vicat Heat Deflection Tester determines Vicat softening temperature (VST) by applying a fixed force (10N or 50N) through a standard Ø1 mm test head while the temperature rises at a controlled rate.
When the penetration/deflection reaches the specified value, the system records the temperature and automatically stops and starts the cooling process.
Each working station includes its own temperature and deflection sensors, and the display shows real-time data for each specimen during the test.

Technical Specifications

Standards & purpose

  • Product serial: QC-662B.
  • Listed standard confirmation: ASTM D648, ISO 75-1.
  • Industry: Plastic, Rubber.

Core specifications

Temperature range Room temperature up to 300°C.
Heating rate 50°C per hour (adjustable).
Test method loads Method A: 10N; Method B: 50N.
Deflection / penetration reading 0.001 – 3.000 mm.
Test head diameter Ø1 mm.
Temperature equalization Circulation flow.
Cooling method Water cooling.
Stations 1, 2, or 3 stations.
Power Single phase 220VAC.

Specimen requirements (important)

  • Use at least two flat, smooth, parallel specimens with thickness 3 to 6.5 mm and area at least 10 × 10 mm² or Ø10 mm.
  • If specimen thickness is above 6 mm, reduce it by half on one side and keep the other side unchanged.
  • If specimen thickness is below 2.5 mm, stack the specimen with fewer than 3 other materials to make the combination at least 3 mm thick.

Interface & productivity

  • Touchscreen interface guides users step-by-step, designed to reduce test errors and shorten setup time.
  • Display shows temperature and LVDT displacement at each station and records results when reaching the deflection value.
  • Jigs are replaceable.

Support notes (merged)

  • Cometech states training is provided by professional engineers and includes complete training content.
  • Cometech states warranty-period maintenance support and parts availability (via its ERP warehousing system) within 10 years after sale.
  • Cometech states CE certification from TUV and that products follow CE standard rules from design to manufacturing.