Home / Products / Bayerteq / Bayerteq Vicat A6060 – HDT / Vicat Thermal Deflection Tester
Bayerteq Vicat A6060 – HDT / Vicat Thermal Deflection Tester
Click to zoom
Bayerteq Vicat A6060 Workstation and Frame Rigidity

Bayerteq Vicat A6060 – HDT / Vicat Thermal Deflection Tester

SKU: BTQ-VIC-001
  • Precision thermal deflection and softening point testing system for thermoplastics, thermosets, and pipe materials
  • Full compliance with ISO 75, ISO 306, ASTM D648, ASTM D1525, and ISO 2507
  • Configurations available with 3, 4, 5, or 6 independent test stations with individual temperature sensors
  • Controlled testing temperatures up to 300 °C with dual heating rates of 50 °C/h and 120 °C/h
  • Ultra-low frame thermal expansion (0.005 mm / 100 °C) and deformation accuracy within 0.005 mm
  • Motorized automatic station lifting, automatic weight loading, integrated smoke exhaust system, and PC software
Interested?

Request a quote for this product

The HDT Vicat tester (Model Vicat A6060) manufactured by Bayerteq is an advanced thermal deflection testing system engineered for determining the Heat Deflection Temperature (HDT) and Vicat Softening Temperature (VST) of raw polymers, rigid plastics, and pipe fittings. Designed in strict accordance with international standards including ISO 75, ISO 306, ASTM D648, ASTM D1525, and ISO 2507, this high-precision instrument delivers reliable thermal characterization for material qualification, compounding, and certification laboratories.

Heat resistance is a critical operational parameter for polymers used in automotive, plumbing, and structural engineering. The Bayerteq HDT Vicat tester heats a methyl silicone oil bath at precise, standardized heating rates (50 °C/h or 120 °C/h) while applying calibrated flexural stresses (Method HDT A, B, C) or indenter needle loads (Vicat A50, A120, B50, B120), continuously recording the exact temperature at which standard deflection or 1 mm needle penetration occurs.

HDT Vicat Tester Architecture & Station Capabilities

The Vicat A6060 series is engineered with heavy-duty automated mechanics and high-resolution digital sensing:

  • Multi-Station Modular Capacity (3 to 6 Stations): Available with 3, 4, 5, or 6 test stations. Each station features an independent temperature measuring sensor directly adjacent to the specimen, guaranteeing uniform thermal monitoring across all positions.
  • Ultra-Low Thermal Expansion Specimen Frames: Manufactured from advanced low-expansion alloy materials limiting frame thermal drift to just 0.005 mm per 100 °C, eliminating measurement distortion under thermal ramps up to 300 °C.
  • Motorized Automatic Lifting & Weight Loading: Test stations lift and lower automatically into the oil bath via motorized drives. Calibrated test weights load and offload automatically during the lifting cycle to minimize operator handling.
  • High-Resolution Digital Micrometers: Electronic digital deformation gauges with dedicated communication interfaces deliver displacement measurement accuracy within 0.005 mm.
  • Environmental & Thermal Protection: Integrated forced smoke exhaust ventilation extracts oil fumes safely from the testing bay, backed by an independent secondary thermal circuit that halts heating if bath temperature exceeds permissible thresholds.

Operated via an integrated color touchscreen or connected PC with Bayerteq software, this HDT Vicat tester logs real-time temperature-deflection curves and exports compliance test certificates automatically.

Bayerteq Vicat A6060 Series – Technical Specifications

Parameter Specification Details
Applicable Standards ISO 75 (Part 1, 2, 3), ISO 306, ASTM D648, ASTM D1525, ISO 2507, DIN 53460, DIN 53461
Number of Test Stations 3, 4, 5, or 6 stations (Independent station design)
Temperature Range Ambient room temperature up to +300 °C
Temperature Accuracy Max ±0.5 °C (Dedicated temperature measuring point at every individual station)
Standard Heating Rates 50 °C/h ± 5 °C/h and 120 °C/h ± 10 °C/h (Heating rate accuracy: max 1% / 6 min)
Deformation Measurement Device High-precision digital indicator gauge with digital electronic communication interface
Deformation Measurement Range & Error 0 – 10 mm range; maximum measurement error ≤ 0.005 mm
Thermal Expansion Coefficient ≤ 0.005 mm / 100 °C (Special low-expansion alloy specimen frames)
Sample Support Spans 64 mm and 100 mm (Supports flatwise and edgewise HDT test positioning)
Vicat Indenter Tip Circular needle tip with hardened flat cross-section of 1.000 mm² ± 0.015 mm²
Bath Liquid Medium Methyl silicone oil with continuous motorized magnetic/impeller circulation stirring
Automation Features Motorized automatic station lift, automatic weight loading/offloading, built-in smoke exhaust
Control & Data Interface Color touchscreen and external PC software running on Windows with automatic curve logging
Electrical Power Supply 220 VAC ± 10%, 50 Hz, Single Phase; CE Certified

Key Operational & Engineering Advantages

Dedicated Sensor per Station

Each individual station is equipped with its own dedicated RTD temperature sensor positioned at the sample, eliminating thermal gradients across the bath.

Minimal Frame Thermal Drift

Specially developed frame metallurgy restricts thermal expansion to 0.005 mm / 100 °C, preventing false deflection readings during heating.

Motorized Station Lifting & Loading

Automated electric lifting mechanism lowers and raises the test frames smoothly, with automatic weight placement during the loading process.

Automatic Smoke Exhaust Fan

Integrated vapor extraction hood captures silicone oil fumes at elevated temperatures, maintaining clean, safe air quality in the laboratory.

Digital Micrometer Accuracy

High-precision digital micrometers with electronic communication provide 0.005 mm accuracy, delivering repeatable data even under the lightest loads.

Dual Protection Safety Loop

Independent secondary hardware temperature circuit cuts heater power immediately if oil bath temperature exceeds programmed limits.

System Architecture & Optional Tooling

1. Station Capacity Selection

Standard model configurations with 3, 4, 5, or 6 test stations configured to specific testing throughput requirements.

2. Calibrated Test Weight Sets

Precision stainless steel weight sets conforming to ISO 75 and ISO 306 load requirements for HDT Method A, B, C and Vicat 10 N / 50 N.

3. Indenters and Support Anvils

Vicat 1.0 mm² indenter needles and interchangeable 3-point flexure anvils with 64 mm and 100 mm spans.

4. Bayerteq PC Software & Workstation

Windows-compatible testing software, dual-channel temperature control interface, automated curve plotting, and PDF test report generation.

Industry Standards & Practical Applications

The Bayerteq HDT Vicat tester is essential equipment for polymer compounding, resin manufacturing, and plastics testing laboratories:

  • Vicat Softening Temperature (ISO 306 / ASTM D1525): Measuring the softening point of thermoplastics (PE, PP, PVC, ABS, PS, PC) under 10 N or 50 N loads at 50 °C/h or 120 °C/h.
  • Heat Deflection Temperature Under Load (ISO 75 / ASTM D648): Determining deflection temperatures for rigid plastics and reinforced composites under flexural stresses of 0.45 MPa, 1.80 MPa, or 8.0 MPa.
  • Thermoplastic Pipes and Fittings (ISO 2507): Verifying heat resistance and wall softening compliance of PVC-U, PVC-C, and polyolefin pressure pipes.
  • Compound Formulation & Additive R&D: Evaluating the effect of mineral fillers, glass fibers, plasticizers, and flame retardants on high-temperature rigidity.
  • Quality Control of Injection Molded Articles: Ensuring components maintain dimensional stability under automotive under-the-hood or hot industrial service temperatures.